solis data logger offline solis data logger offline

Status indicator, easy to display working status, RESET button, one key to send data, convenient debugging, Number of connected inverters (Connect the inverters by RS485 cables. or, which is default value. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Victor is the author of this solution article. Manage Settings Reliability Safety Capacity WiFi Data Logger. Data Logger into the port and be sure to secure it by tightening the black connector. it has come back on line, so it is obviously a connection issue, Xi Jinping must have forgot to reboot the GFW this morning, Copyright 2000- 2023 Boards Software Limited, If you have a new account but are having problems posting or verifying your account, please email us on, Hello All, This is just a friendly reminder to read the Forum Charter where you wish to post before posting in it. Solis monitoring system can be monitored remotely by WIFI and GPRS to provide users accurate and comprehensive data analysis and fault alarm at any time and place, this makes product operation more stable and reliable, and realize stable and intelligent operation and maintenance management services. You should see a message that says "Bound Successfully" and now you will need to set up the logger on the localWiFinetwork. Tap the Plant icon in the bottom left corner of the screen, Tap the plus sign in the top right corner and then tap "Add Plant", Fill in all of the required fields on the "Create Plant" page and then tap "Done" in the top right corner, Tap "Create Plant" to finish making a system inSolisCloud- tap "View Plant" once it gives you a big check mark, When the plant page opens, you will receive a message saying "No datalogger was added, please add a datalogger" tap "Add" if theWiFidata logger is plugged into the bottom of the inverter, A scanner will automatically come up. Go to your web browser - Input 10.10.100.254 4. *, We appreciate your effort and will try to fix the article. This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. The [RESET] button on the back is used for the connection. However, there is no guarantee that interference will not occur in a particular installation. View the total data of your PV plant. Then plug the Wifi Data Logger into the port and be sure to secure it by tightening the black connector. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. Then plug the. Hi all, The AutoSave Draft feature is now disabled across the site. You can rerun the wizard and see if that works. Help us improve this article with your feedback. This should serve as a reminder to manually save your drafts if you wish to keep them. My data logger appears to be working fine but I also notice it now glows red, appears to be a red LED inside the logger. Open the Local Connection Status, click. If you are scanning the loggers then be sure to scan the bar code on the logger itself and not the one on the inverter's spec label, see examples of the logger bar codes below: You can learn more about what kind of cookies we use, why, and how from our Privacy policy. Connect to the datalogger - AP_XXXXXXXXXX, 3. Solis WIFI Stick Troubleshooting TOP 5 Issues: 1. Just note that the Freshdesk service is pretty big on some cookies (we love the choco-chip ones), and some portions of Freshdesk may not work properly if you disable cookies. Open a web browser and enter "10.10.100.254" into the address bar 4. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. cordless phone, concrete wall, PV panel and metal wall, to ensure the communication quality. Once you've connected to the "AP" network, return toSolisCloudand then look for the home network that you wish to connect the logger to. If there are symbols in the password, it must be changed or the logger will not connect to it. If its not pingable, the password is good, the signal strength is good then login to the router and check the customers firewall protections. If its not broadcasting conduct this procedure - https://www.youtube.com/watch?v=nUjcDcY8-Ws - If that doesn't fix the issue of it broadcasting please contact your local Solis Service Center and RMA the WIFI Stick. Router signal strength is low 4. If you have not already been registered on, It is highly recommended to first connect your phone to the home network that you wish to connect the, logger to. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. 0:00 / 1:28 Reset instruction for Solis Datalogger Solis 46.7K subscribers Subscribe 130 37K views 3 years ago When the datalogger fails, you can try to reset it to repair. It may also be affected by lighting storms. :). Note that all scripts use Python 3. If there are symbols in the password, it must be changed or the logger will not connect to it. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. account already, then please follow the steps below to create a plant and commission a Solis, Tap "Create Plant" to finish making a system in, - tap "View Plant" once it gives you a big check mark, When the plant page opens, you will receive a message saying "No datalogger was added, please add a datalogger" tap "Add" if the, data logger is plugged into the bottom of the inverter, A scanner will automatically come up. (DLB-W(Wifi),Lan Data Logger, Wifi Data Logger,S3-WIFI-ST,Celluar Data Logger,1500V PLC CCO, Solis-ATR-6K), For the duration of this period Ginlong guarantees the proper functions of the Products. Never lost connection since, so yeah you're probably having WiFi range issue. According to the website my data logger is offline. Copyright@2020 Ginlong Technologies All rights reserved. If its not either move the inverter closer to the router, the router closer to the inverter or use a repeater to boost the strength. Administrators, Computer Games Moderators, Sports Moderators, https://www.boards.ie/discussion/comment/118925467#Comment_118925467, https://www.boards.ie/discussion/comment/118925665#Comment_118925665, https://www.boards.ie/discussion/2058241657/solis-app-gone-off-line, https://www.boards.ie/discussion/comment/118926624#Comment_118926624, Music Production Commercial When I am logged into the data logger via wifi the status says that it is connected and when I test the connection on the server page it seems to be all good. 2. Interaction, Climate Change, Sustainability & An example of data being processed may be a unique identifier stored in a cookie. Yes 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stick, Solis DLS-G GPRS Datalogger setup and troubleshooting, Adding a new inverter to an existing EPM set-up, EPM 5G Plus- Abnormal Offline on Soliscloud. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. I too have recently tried to connect to the Ginlong data logger without success. With permission, you can test the firewall by removing the firewall for 5 minutes to see if the communication with the remote server changes to pingable. If the WIFI stick doesn't show a connected inverter check the address of the inverter. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. Copyright@2020 Ginlong Technologies All rights reserved, If the network is not appearing, press and hold the Reset button down for 10 seconds until both NET and COM lights start to flash simultaneously, This network must be 2.4GHz as 5GHz networks are not supported. 5. You can select the corresponding server information according to the model of data logger used by the plant. Required fields are marked *. https://www.youtube.com/watch?v=0F0aGeTOYw8. If you hate cookies, or are just on a diet, you can disable them altogether too. Note* You can use your phone, tablet or laptop. Or directly download from APP Store or Google Play Store by searching SolisCloud. No-Grid - El inversor no reconoce la red. Open the Local Connection Status, clickon Properties, select internet protocol IPv4(TCP/IPv4). The device must be installed away from the strong magnetic field produced by large electrical appliances such as microwave ovens, refrigerators, telephone, metal walls, etc. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. Solis Plant Offline, Please Check Devices and Netwo. Monitoring Accessory Configured But Still Won't Link? You can learn more about what kind of cookies we use, why, and how from our Privacy policy. Wi-Fi trensmitting power: 802.11b/g/n: +20dBm/+18dBm/15dBm (Max) Data collection intervals: 5 minutes (adjustable:1-20 minutes) Preferences setting: Web server/Serial AT instruction. This new monitoring platform will empower you like never before. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. The

Flirty Response To Where Have You Been All My Life, Texas Roadhouse Specials, Can You Call The Fire Department For A Question, Texarkana Arkansas School District Superintendent, During Longshore Drift, Sand Grains Move, Articles S